Skip to content

Sygnalizacja przyzywowa, panele nadłóżkowe – INSEL

Streamlink the work of medical staff

We ensure patient safety and comfort

We increase the prestige of institution

Bed-side devices

AP 700-1

Digital bedside devices with a pear-shaped manipulator. The manipulator is terminated with a small JACK plug. Thanks to this, the possibility of damaging both the socket and the plug when tugging on the cable has been eliminated. The AP 700-1 device (with a one-button manipulator) enables the patient to turn on the paging signal. This signal contains the coded number of the bed, which allows the personnel to be informed exactly where the signal was triggered. The two-color LED clearly informs about the inclusion of the paging signal and its arrival at the duty room. In case of damage or lack of the manipulator, information about it is immediately sent to the signaling matrix in the nursing station. Additionally, it enables the personnel to activate the SECOND CALL signal.

AP 700-3

Digital bedside devices with a pear-shaped manipulator. The manipulator is terminated with a small JACK plug. Thanks to this, the possibility of damaging both the socket and the plug when tugging on the cable has been eliminated. The AP 700-3 device (with a three-button manipulator) enables the patient to turn on the paging signal. This signal contains the coded number of the bed, which allows the personnel to be informed exactly where the signal was triggered. The two-color LED clearly informs about the inclusion of the paging signal and its arrival at the duty room. In case of damage or lack of the manipulator, information about it is immediately sent to the signaling matrix in the nursing station. Additionally, it enables the personnel to activate the SECOND CALL signal. AP700-3 devices, apart from the possibility of summoning help, also have the option of controlling local and night lighting in over-bed panels of other manufacturers.

AP 400

Digital bedside device with ‘pear shaped’ manipulator. Allows a patient to trigger a page signal. This signal contains a coded number of bed which enables accurate location of the place of signal activation. Bi-color LED’s diode clearly informs that the paging signal was activated and its getting to the nurses’ station. In case of damage or lack of manipulator, the information is immediately sent to the matrix signal system in the nurses’ station. Additionally, it enables staff to trigger SECOND CALL signal.

AP 410

Digital bedside device with an alarm button. Allows a patient to trigger a page signal. This signal contains a coded number of bed which enables accurate location of the place of signal activation. Bi-color LED’ diode clearly informs that the paging signal was activated and its getting to the nurses’ station. Additionally, it enables staff to trigger SECOND CALL signal.

AP 420

Analog bedside device with a ‘pear shaped’ manipulator. Allows a patient to trigger a page signal and pass the signal to the alarm signal system. No information concerning the bed number is sent. Additionally, it enables staff to trigger SECOND CALL signal.

AP 430

Analog bedside device with and alarm button. Allows a patient to trigger a page signal and pass the signal to the matrix signal system. No information concerning the bed number is sent. Additionally, it enables staff to trigger SECOND CALL signal.

PG 300

The PG 300 apparatus is used for paging in dialysis stations etc. It enables the patient to trigger of the page signal. The signal contains coded number of station that enables to clear identification of the signal triggering place. It enables the ATTENDANCE CONFIRMATION and CANCELLING of the triggered page signals. Additionally, the apparatus enables the personnel to trigger SECOND CALL or DOCTOR CALL. The LED light in the manipulator is clearly notifying of the triggered page signal and its arrival at the nurses station – when the push-button is pushed the LED illuminates red. When the signal reaches the personnel it changes from red to green. In case the manipulator is defective or missing the signalling matrix indicates the error immediately.